Do you really know the volume of your Anilox rolls?

For a long time printer / converters have assumed that the volume readings on anilox rolls ordered to the same specification from different manufac- turers are the same.

Specifying  an anilox roll by line count and volume seems     straightforward. Simply choose  your line count and carrying capac- ity and you might think any anilox supplier would provide a  roll that delivered the same volume of ink. That’s the problem. New field research has uncovered  no clear correlation to the volume measurements be- ing generated by the various anilox suppliers.  Because of this, there is a significant  technical challenge to overcome due to the absence of a measurement standard for measuring anilox cell volume.

 

Troika Systems Limited (UK) and its partner The Provident Group
(USA) have ascertained that the various measurement techniques be- ing used by manufacturers is the reason why volume readings aren’t the same.  These techniques include liquid volume, scanning micro- scopes, white  light interferometry and microscopes for measuring openings and depths and calculating the theoretical volume from a chart.

 

In 2007, Troika Systems launched AniCAM,  an effective benchmark tool used to manage anilox inventories.  AniCAM  allows users to mea- sure and record anilox inventory details from brand new rolls to the end of their usable life.  Measuring volume before and after clean- ing is a vital part of any anilox management or press standardization program.

 

Collecting data from the various types of volume measuring tech- niques has uncovered some noteworthy  results. It has been an inter- esting learning experience and one worth sharing.

 

The Provident Group
had a banded anilox roll manufactured with 12 bands from 1200-100 lpi / 500-40  lpcm (see attached photo). This roll has been sent to anilox manufacturers in North America and Europe with the request that they measure the bands using their standard method. The results gathered to date are shown on the chart below. The considerable differences measured from the same bands on the same roll are frankly astonishing. Variations between 28% and 141% in volume on the bands are seen from the 13 participating compa- nies. Furthermore, the variations in depth measurements of the anilox cells, which is the critical value used by manufacturers using the chart method of volume calculation, varies by as much  as 42%.

 

This research has highlighted the significant variations in readings between various measurement methods. We now know we are deal- ing with a complex industry wide problem that few are aware of and no one realized the magnitude until now. Our work highlights that volume  measurements  as they are being done today are a relative measure and only valid when done using the same procedures under controlled conditions.

 

Troika Systems and The Provident Group
are very grateful  to all the participating anilox manufacturers for their keen participation  and wish to thank Apex Europe, Harper USA, Harper Europe, Interflex Laser Engravers, Pamarco Global Graphics USA, Sandon Global, Un- gricht, Zecher and others for their willing and active participation in this important industry  research. The project is ongoing  and other anilox manufacturers will be contributing data in the near future.

 

It is hoped that this effort benefits and advances our industry. It has been a unique level of cooperation and trust that has got us to this point. The results have been shared with the companies that partici- pated. Please note  that all the manufacturers have methods  within their respective operations insuring that their measurements are con- sistent  as possible  to achieve roll to roll repeatability in production.

 

LPI / LPCM

Minimum BCM reading

Maximum BCM reading

Percentage difference between manufacturers readings

Band 1 1200 / 500

1.10

1.81

65%

Band 2 1000 / 400

1.70

2.58

52%

Band 3 800 / 320

1.28

3.10

141%

Band 4 700 / 280

2.90

5.35

84%

Band 5 500 / 200

3.30

6.32

91%

Band 6 400 / 160

4.03

8.26

105%

Band 7 300 / 120

5.26

8.00

52%

Band 8 250 / 100

6.84

9.87

44%

Band 9 200 / 80

9.55

12.19

28%

Band 10 180 / 70

8.97

13.50

51%

Band 11 150 / 60

10.77

17.74

65%

Band 12 100 / 40

13.87

26.33

90%

 

A comparison between Anilox measuring methods clearly shows a signi´¼ücant range in volume readings.

Research is property of Troika Systems Limited & The Provi- dent Group.

For more detail explanation of the research please contact

phil.hall@troika-systems.com or dallen@providentgrp.com

 